The safe operation of silent generator is crucial for ensuring the stability and reliability of power supply. The following are several points to note regarding the safe operation of silent generators:
1、 Operators need to be professional and familiar with the unit
The personnel operating the silent generator must possess corresponding professional knowledge, be familiar with the structure and working principle of the unit, and strictly follow safety operating procedures. During the operation, it is necessary to wear labor protection equipment and maintain a safe distance from live equipment.
2、 Preparation and inspection before starting the silent generator
Before starting the silent generator, a comprehensive inspection is required to ensure that the oil, water, and gas pipeline connections are firm and correct, the output connections are firm, and there are no debris near the flywheel. At the same time, it is necessary to check whether the oil level of the lubrication system is within the normal range and whether the cooling water tank level is normal. In addition, after connecting the fuel system of the new engine, the air in the fuel filter and fuel injection pump should be eliminated to ensure that the high-pressure fuel pipe is filled with diesel.
3、 Observation and maintenance of silent generator operation
During the operation of the unit, close attention should be paid to the dynamic operation and instrument parameters. If there are any abnormal phenomena, the cause should be immediately identified and eliminated in a timely manner. At the same time, daily maintenance and upkeep of the unit should be carried out, including changing engine oil, cleaning filters, etc. In addition, the unit is strictly prohibited from overloading or idling for a long time to avoid damage to the unit.
4、 Emergency shutdown measures for silent generator
In case of emergencies or malfunctions during the operation of the unit, emergency shutdown measures should be taken immediately to avoid damage to the unit and personnel. Emergency parking measures include quickly pulling the parking lever to the parking space or pressing the emergency stop button for safety protection measures.
5、 Storage and Preservation of Silent Generator
If the silent generator needs to be stored for a long time, comprehensive cleaning and maintenance work should be carried out, new lubricating oil should be replaced, the coolant in the water tank should be drained, and rust prevention treatment should be carried out. At the same time, the storage location should be dry and ventilated, avoiding overheating, overcooling, or exposure to rain and sunlight. In addition, the starting battery of the unit also needs to be charged and maintained regularly.